UL94 Flame Retardant Rating - Look Here If You Don't Understand!

Jun 08, 2026

Leave a message

In product structural design, especially in scenarios involving high temperature, high pressure, electrical transmission, or personnel contact, the flame retardant performance of the product enclosure is directly related to usage safety, compliance for market launch, and risk prevention and control. The UL94 flame retardant rating standard is a core compliance requirement for most product enclosures. For example, products we often work on for clients, such as electricity meters, connectors, and other high-temperature, high-voltage products, have the UL94 certification for their enclosures as a mandatory requirement because they operate in long-term electrified and heat-generating environments.

UL 94 is currently the most universally adopted standard for plastic flame retardant ratings worldwide. Its core is evaluating four key indicators: the material's self-extinguishing capability upon flame removal, burning time, whether it drips, and whether the drips are flaming and ignite other materials. If we can understand it in our design work, we won't face pitfalls when selecting materials, reviewing specifications, or performing certifications.

 

I. Overview of UL 94 Ratings (3 major categories, 12 levels)

Divided into 3 groups based on material type and testing method. Within each group, a higher level indicates better flame retardancy:

General Rigid Plastics (Most Common): 5VA > 5VB > V-0 > V-1 > V-2 > HB

Foamed Plastics: HF-1 > HF-2 > HBF

Thin Films / Sheets: VTM-0 > VTM-1 > VTM-2

 

II. General Grades (HB / V-2 / V-1 / V-0): Easy to Understand

1,HB: Horizontal Burning (Lowest Flame Retardancy)

Test: Positioned horizontally, flame applied for 30 seconds.

Criteria:

Thickness 3–13mm: Burning rate ≤ 40 mm/min

Thickness < 3mm: Burning rate ≤ 70 mm/min

Or self-extinguishes before the 100mm mark.

Characteristics: Only retards flame, does not self-extinguish, can sustain combustion.

Applications: Internal components with no fire safety requirements.

 

HB Horizontal Burning Lowest Flame Retardancy

 

2,V-2 / V-1 / V-0: Vertical Burning (Mainstream for Electronics & Appliances)

Test: Specimen vertical, two 10-second flame applications. Measures: individual after-flame times (t1, t2), total after-flame time for 5 specimens, afterglow time, presence of flaming drips, and whether drips ignite cotton below.

 

V-2  V-1  V-0 Vertical Burning

 

 

III. 5VA / 5VB: Highest Levels (Equipment Enclosures / Structural Parts)

Test: More stringent: five 5-second flame applications + glowing wire impact.

5VB: Allows burn-through, but must self-extinguish upon flame removal, with no flaming drips igniting cotton.

5VA: Does not​ allow burn-through, must self-extinguish, with no flaming drips igniting cotton.

Applications: Cabinets, large equipment enclosures, high-safety structural parts.

 

5VA  5VB Highest Levels

 

IV. Film Grade VTM / Foam Grade HF

VTM-0 / -1 / -2 (Thin Films < 0.76mm)

Rules similar to V grades, but specimens are thinner and tested hanging vertically.

VTM-0 ≈ V-0, VTM-2 ≈ V-2 (allows drips that may ignite cotton).

[Image: Specimen setup diagrams (front, side, back views)]

HF-1 / HF-2 / HBF (Foam)

HF-1: No flaming drips, does not ignite cotton, extinguishes quickly upon flame removal.

HF-2: Allows a small amount of dripping, does not ignite cotton.

HBF: Horizontal burning, only slow burning, does not self-extinguish.

 Film Grade VTM  Foam Grade HF

 

V. Three Key Points for Reading Specifications / Yellow Cards (Avoiding Pitfalls)

Must Check Thickness

Same material: Thicker is easier to achieve a higher rating.

Example: Marked as V-0 (1.5mm) → Only meets V-0 at 1.5mm thickness. Thinner versions may only achieve V-2.

Rating Order (High to Low)

5VA > 5VB > V-0 > V-1 > V-2 > HB

Common for electronics: V-0 or V-1

For lower cost: V-2 / HB

How to Read a UL Yellow Card

Material: Material type

Flame Class: Flame retardant rating (includes thickness)

Example: V-0 (2.0mm) → Meets V-0 at 2.0mm thickness.

 

Example UL Yellow Card with key fields highlighted

 

(Content description for image: Example UL Yellow Card showing fields like Material ID, RTI, Manufacturer, and the crucial "Flame Class: V-0 (2.0mm)" indicating the rating is valid at that thickness.)

Send Inquiry